| INTERNATIONAL PROTECTION RATING “IP CODE” |
|
|
|
| IP CODE |
FIRST DIGIT (SOLIDS) |
SECOND DIGIT (LIQUIDS) |
| IP00 |
NOT PROTECTED FROM SOLIDS |
NOT PROTECTED FROM LIQUIDS |
| IP01 |
NOT PROTECTED FROM SOLIDS |
PROTECTED FROM CONDENSATION |
| IP02 |
NOT PROTECTED FROM SOLIDS |
PROTECTED FROM WATER SPRAY LESS THAN 15 DEGREES FROM VERTICAL |
| IP03 |
NOT PROTECTED FROM SOLIDS |
PROTECTED FROM WATER SPRAY LESS THAN 0 DEGREES FROM VERTICAL |
| IP04 |
NOT PROTECTED FROM SOLIDS |
PROTECTED FROM WATER SPRAY FROM ANY DIRECTION |
| IP05 |
NOT PROTECTED FROM SOLIDS |
PROTECTED FROM LOW PRESSURE WATER JETS FROM ANY DIRECTION |
| IP06 |
NOT PROTECTED FROM SOLIDS |
PROTECTED FROM HIGH PRESSURE WATER JETS FROM ANY DIRECTION |
| IP07 |
NOT PROTECTED FROM SOLIDS |
PROTECTED FROM IMMERSION BETWEEN 15 CENTIMETERS AND 1 METER IN DEPTH. |
| IP08 |
NOT PROTECTED FROM SOLIDS |
PROTECTED FROM LONG TERM IMMERSION UP TO A SPECIFIED PRESSURE |
| IP10 |
PROTECTED FROM TOUCH BY HANDS GREATER THAN 50 MILLIMETERS |
NOT PROTECTED FROM LIQUIDS |
| IP11 |
PROTECTED FROM TOUCH BY HANDS GREATER THAN 50 MILLIMETERS |
PROTECTED FROM CONDENSATION |
| IP12 |
PROTECTED FROM TOUCH BY HANDS GREATER THAN 50 MILLIMETERS |
PROTECTED FROM WATER SPRAY LESS THAN 15 DEGREES FROM VERTICAL |
| IP13 |
PROTECTED FROM TOUCH BY HANDS GREATER THAN 50 MILLIMETERS |
PROTECTED FROM WATER SPRAY LESS THAN 60 DEGREES FROM VERTICAL |
| IP14 |
PROTECTED FROM TOUCH BY HANDS GREATER THAN 50 MILLIMETERS |
PROTECTED FROM WATER SPRAY FROM ANY DIRECTION |
| IP15 |
PROTECTED FROM TOUCH BY HANDS GREATER THAN 50 MILLIMETERS |
PROTECTED FROM LOW PRESSURE WATER JETS FROM ANY DIRECTION |
| IP16 |
PROTECTED FROM TOUCH BY HANDS GREATER THAN 50 MILLIMETERS |
PROTECTED FROM HIGH PRESSURE WATER JETS FROM ANY DIRECTION |
| IP17 |
PROTECTED FROM TOUCH BY HANDS GREATER THAN 50 MILLIMETERS |
PROTECTED FROM IMMERSION BETWEEN 15 CENTIMETERS AND 1 METER IN DEPTH. |
| IP18 |
PROTECTED FROM TOUCH BY HANDS GREATER THAN 50 MILLIMETERS |
PROTECTED FROM LONG TERM IMMERSION UP TO A SPECIFIED PRESSURE |
| IP20 |
PROTECTED FROM TOUCH BY FINGERS AND OBJECTS GREATER THAN 12 MILLIMETERS |
NOT PROTECTED FROM LIQUIDS |
| IP21 |
PROTECTED FROM TOUCH BY FINGERS AND OBJECTS GREATER THAN 12 MILLIMETERS |
PROTECTED FROM CONDENSATION |
| IP22 |
PROTECTED FROM TOUCH BY FINGERS AND OBJECTS GREATER THAN 12 MILLIMETERS |
PROTECTED FROM WATER SPRAY LESS THAN 15 DEGREES FROM VERTICAL |
| IP23 |
PROTECTED FROM TOUCH BY FINGERS AND OBJECTS GREATER THAN 12 MILLIMETERS |
PROTECTED FROM WATER SPRAY LESS THAN 60 DEGREES FROM VERTICAL |
| IP24 |
PROTECTED FROM TOUCH BY FINGERS AND OBJECTS GREATER THAN 12 MILLIMETERS |
PROTECTED FROM WATER SPRAY FROM ANY DIRECTION |
| IP25 |
PROTECTED FROM TOUCH BY FINGERS AND OBJECTS GREATER THAN 12 MILLIMETERS |
PROTECTED FROM LOW PRESSURE WATER JETS FROM ANY DIRECTION |
| IP26 |
PROTECTED FROM TOUCH BY FINGERS AND OBJECTS GREATER THAN 12 MILLIMETERS |
PROTECTED FROM HIGH PRESSURE WATER JETS FROM ANY DIRECTION |
| IP27 |
PROTECTED FROM TOUCH BY FINGERS AND OBJECTS GREATER THAN 12 MILLIMETERS |
PROTECTED FROM IMMERSION BETWEEN 15 CENTIMETERS AND 1 METER IN DEPTH. |
| IP28 |
PROTECTED FROM TOUCH BY FINGERS AND OBJECTS GREATER THAN 12 MILLIMETERS |
PROTECTED FROM LONG TERM IMMERSION UP TO A SPECIFIED PRESSURE |
| IP30 |
PROTECTED FROM TOOLS AND WIRES GREATER THAN 2.5 MILLIMETERS |
NOT PROTECTED FROM LIQUIDS |
| IP31 |
PROTECTED FROM TOOLS AND WIRES GREATER THAN 2.5 MILLIMETERS |
PROTECTED FROM CONDENSATION |
| IP32 |
PROTECTED FROM TOOLS AND WIRES GREATER THAN 2.5 MILLIMETERS |
PROTECTED FROM WATER SPRAY LESS THAN 15 DEGREES FROM VERTICAL |
| IP33 |
PROTECTED FROM TOOLS AND WIRES GREATER THAN 2.5 MILLIMETERS |
PROTECTED FROM WATER SPRAY LESS THAN 60 DEGREES FROM VERTICAL |
| IP34 |
PROTECTED FROM TOOLS AND WIRES GREATER THAN 2.5 MILLIMETERS |
PROTECTED FROM WATER SPRAY FROM ANY DIRECTION |
| IP35 |
PROTECTED FROM TOOLS AND WIRES GREATER THAN 2.5 MILLIMETERS |
PROTECTED FROM LOW PRESSURE WATER JETS FROM ANY DIRECTION |
| IP36 |
PROTECTED FROM TOOLS AND WIRES GREATER THAN 2.5 MILLIMETERS |
PROTECTED FROM HIGH PRESSURE WATER JETS FROM ANY DIRECTION |
| IP37 |
PROTECTED FROM TOOLS AND WIRES GREATER THAN 2.5 MILLIMETERS |
PROTECTED FROM IMMERSION BETWEEN 15 CENTIMETERS AND 1 METER IN DEPTH. |
| IP38 |
PROTECTED FROM TOOLS AND WIRES GREATER THAN 2.5 MILLIMETERS |
PROTECTED FROM LONG TERM IMMERSION UP TO A SPECIFIED PRESSURE |
|
|
|
| INTERNATIONAL PROTECTION RATING (IP CODE) CONTINUED |
| IP CODE |
FIRST DIGIT (SOLIDS) |
SECOND DIGIT (LIQUIDS) |
| IP40 |
PROTECTED FROM TOOLS AND SMALL WIRES GREATER THAN 1 MILLIMETER |
NOT PROTECTED FROM LIQUIDS |
| IP41 |
PROTECTED FROM TOOLS AND SMALL WIRES GREATER THAN 1 MILLIMETER |
PROTECTED FROM CONDENSATION |
| IP42 |
PROTECTED FROM TOOLS AND SMALL WIRES GREATER THAN 1 MILLIMETER |
PROTECTED FROM WATER SPRAY LESS THAN 15 DEGREES FROM VERTICAL |
| IP43 |
PROTECTED FROM TOOLS AND SMALL WIRES GREATER THAN 1 MILLIMETER |
PROTECTED FROM WATER SPRAY LESS THAN 60 DEGREES FROM VERTICAL |
| IP44 |
PROTECTED FROM TOOLS AND SMALL WIRES GREATER THAN 1 MILLIMETER |
PROTECTED FROM WATER SPRAY FROM ANY DIRECTION |
| IP45 |
PROTECTED FROM TOOLS AND SMALL WIRES GREATER THAN 1 MILLIMETER |
PROTECTED FROM LOW PRESSURE WATER JETS FROM ANY DIRECTION |
| IP46 |
PROTECTED FROM TOOLS AND SMALL WIRES GREATER THAN 1 MILLIMETER |
PROTECTED FROM HIGH PRESSURE WATER JETS FROM ANY DIRECTION |
| IP47 |
PROTECTED FROM TOOLS AND SMALL WIRES GREATER THAN 1 MILLIMETER |
PROTECTED FROM IMMERSION BETWEEN 15 CENTIMETERS AND 1 METER IN DEPTH. |
| IP48 |
PROTECTED FROM TOOLS AND SMALL WIRES GREATER THAN 1 MILLIMETER |
PROTECTED FROM LONG TERM IMMERSION UP TO A SPECIFIED PRESSURE |
| IP50 |
PROTECTED FROM LIMITED DUST INGRESS |
NOT PROTECTED FROM LIQUIDS |
| IP51 |
PROTECTED FROM LIMITED DUST INGRESS |
PROTECTED FROM CONDENSATION |
| IP52 |
PROTECTED FROM LIMITED DUST INGRESS |
PROTECTED FROM WATER SPRAY LESS THAN 15 DEGREES FROM VERTICAL |
| IP53 |
PROTECTED FROM LIMITED DUST INGRESS |
PROTECTED FROM WATER SPRAY LESS THAN 60 DEGREES FROM VERTICAL |
| IP54 |
PROTECTED FROM LIMITED DUST INGRESS |
PROTECTED FROM WATER SPRAY FROM ANY DIRECTION |
| IP55 |
PROTECTED FROM LIMITED DUST INGRESS |
PROTECTED FROM LOW PRESSURE WATER JETS FROM ANY DIRECTION |
| IP56 |
PROTECTED FROM LIMITED DUST INGRESS |
PROTECTED FROM HIGH PRESSURE WATER JETS FROM ANY DIRECTION |
| IP57 |
PROTECTED FROM LIMITED DUST INGRESS |
PROTECTED FROM IMMERSION BETWEEN 15 CENTIMETERS AND 1 METER IN DEPTH. |
| IP58 |
PROTECTED FROM LIMITED DUST INGRESS |
PROTECTED FROM LONG TERM IMMERSION UP TO A SPECIFIED PRESSURE |
| IP60 |
PROTECTED FROM TOTAL DUST INGRESS |
NOT PROTECTED FROM LIQUIDS |
| IP61 |
PROTECTED FROM TOTAL DUST INGRESS |
PROTECTED FROM CONDENSATION |
| IP62 |
PROTECTED FROM TOTAL DUST INGRESS |
PROTECTED FROM WATER SPRAY LESS THAN 15 DEGREES FROM VERTICAL |
| IP63 |
PROTECTED FROM TOTAL DUST INGRESS |
PROTECTED FROM WATER SPRAY LESS THAN 60 DEGREES FROM VERTICAL |
| IP64 |
PROTECTED FROM TOTAL DUST INGRESS |
PROTECTED FROM WATER SPRAY FROM ANY DIRECTION |
| IP65 |
PROTECTED FROM TOTAL DUST INGRESS |
PROTECTED FROM LOW PRESSURE WATER JETS FROM ANY DIRECTION |
| IP66 |
PROTECTED FROM TOTAL DUST INGRESS |
PROTECTED FROM HIGH PRESSURE WATER JETS FROM ANY DIRECTION |
| IP67 |
PROTECTED FROM TOTAL DUST INGRESS |
PROTECTED FROM IMMERSION BETWEEN 15 CENTIMETERS AND 1 METER IN DEPTH. |
| IP68 |
PROTECTED FROM TOTAL DUST INGRESS |
PROTECTED FROM LONG TERM IMMERSION UP TO A SPECIFIED PRESSURE |
| IP69K |
PROTECTED FROM TOTAL DUST INGRESS |
PROTECTED FROM STEAM-JET CLEANING |
|
|
|
| ref: |
IEC 605, “degrees of Protection Provided by Enclosures” (IP Codes),” Ed. 2.1 (Geneva: International Electrotechnical Commision, 2011) |
|
|
|
| The INTERNATIONAL PROTECTION RATING or “IP CODE” is used to rate enclosures for the degree of ingress of solids, dust, and liquids. |
| The first number following the “IP” covers solids and dust and the second number covers liquids. |